Proven Technology. Advice You Can Trust.
View Cart:    Items 0    Total $0.00   

Customer Log In  Register

Live Chat Help

Shipping Guaranteed
Safe & Reliable
via UPS

Impulse™ EMG Bluetooth Switch

Impulse EMG Bluetooth Switch and Mouse

Computer access with (almost) just a thought. Impulse allows users to completely control their computer using any controllable muscle.

Item# AL11118

Qty:      Add To Cart
  

bookmark this page

A computer control device that responds to the slightest of movements.
  • No wires
  • Integrates with the computer and software you already own
  • Light and stylish enough to wear every day, anywhere
Impulse is an EMG (Electromyography) sensing electrode that senses tiny muscle contractions. Using its patented technology, the Impulse detects and wirelessly transmits the EMG signal to a computer using Bluetooth wireless technology. Impulse's software then processes the activity as a traditional switch “click”. Pairing the Impulse with popular accessibility programs allows users to fully control their computer with the smallest of muscle activity. Wireless active electrode design gives Impulse ultra clean EMG signals and greatly reduces interference. Incredibly fast response time of less than 30 milliseconds.



  • Allows user to completely control their computer using any muscle with voluntary control when used in conjunction with augmentative and alternative communication (AAC) systems
  • Wireless connectivity allows your caregivers to attend to your needs without being hampered by wires or disturbing switch alignment
  • Wireless connectivity allows you to remain connected to the computer even while being transported short distances (such as to the bathroom)
  • Bluetooth Class II connectivity up to 10 M (30 feet)
  • No wires means the Impulse looks better cosmetically than many other similar switches available today
  • Wireless Active Electrode design gives Impulse ultra clean EMG signals and greatly reduces interference
  • Incredibly fast response time (under 30 milliseconds)
  • Integrated with major Speech Generation System Providers
  • Size: 1.9" x 1.1" x 0.6"
  • Weight: 11 oz
  • Range: 30 feet (10 meters)
  • Response time (software adjustable): 16 ms (Ultra fast) to 128 ms (Slow)
  • Active use battery life: 13 hours; 1 hour charge before each use
  • Operating Systems supported: XP (Service Pack 2) and Vista
  • Requires: One available USB (1.1 or 2.0) & switch-accessible software (sold separately)
Impulse™ Bluetooth Switch Includes:
  • 1 Impulse Sensor
  • 1 Impulse Software Installation CD
  • 1 Impulse AC charger
  • 1 Bluetooth Micro Adaptor
  • 30 Disposable Electrodes
  • 30 Alcohol Wipes
  • Quick Start Guide & Support Documentation
*Electrodes are high quality, disposable and single-use. Contact surfaces are pre-jelled with hypoallergenic, water-soluble gel for quick cleanup.




How can I ensure a good skin-to-disposable electrode connection?
There are several key points to remember for a good connection:
Fresh Electrodes - Never try to re-use an electrode. Disposable electrodes are designed for one-time use and may be worn as long as comfortable.
Site Preparation - This is especially important for uses who may have weak EMG. The area must be cleaned and lightly rubbed with an alcohol swab before placing the electrode. Any area more than slightly hairy should be shaved first. This not only will help ensure a good connection but also avoids ripping out hairs when the electrode is removed.
Often what LOOKS like a good connection can actually be a bad connection if the site is not prepped correctly. After a short time with the device you should be able to look at the signal and determine if there is a problem with the connection. When there is a good connection and the user is not contracting and the raw EMG signal should be almost flat lined.
Stabilization - Connections can stabilize with time. An initially bad connection will often stabilize after a while. This fluctuation can be mitigated by carefully preparing the site as described above.

Can I use the same electrode on different people?
No. The electrodes are designed for one-time use. Trying to re-use an electrode will likely result in a bad skin-to-electrode contact.

How often to the disposable electrodes need to be replaced?
Once the electrode is attached to the user, it can be used as long as the patient feels like wearing it. Usually one electrode per day is used.

Why does my Impulse sensor blink red and blue rapidly when I try to turn it on?
You have accidentally placed your Impulse into pairing mode.
When the Impulse switch is Off, holding the connection button down for 3 seconds turns the switch on.
Holding the connection button down for 8 seconds (an additional 5 seconds past the on condition) put the switch into pairing mode, signified by the blinking red and blue lights.
To exit pairing mode, simply turn the switch off (hold connection button for at least 3 seconds) to exit pairing mode and start again.

Can I use the Impulse while the sensor is plugged in/charging?
No. Although the sensor will still transmit while plugged in, the interference from the power supply will overwhelm the EMG signal. Please do not try to use while plugged in.


View More Head/Eye Controlled Input
Questions? Call us!
(888)